This three-key instant electric water heater PCBA supports 85–280 VAC input, selectable P4–P7 power configurations up to 7 kW, 30–55°C temperature control, automatic learning, water-flow sensing, parameter memory, and multi-fault protection for customized heating appliances.
  • Power Supply:

    Switching Power Supply: 85–280 VAC
  • Optional Power Supply:

    Transformer Solution: 180–265 VAC
  • Maximum Power Setting:

    7,000 W
  • Temperature Setting Range:

    30–55°C
  • Control Panel Compatibility:

    Compatible with 4 mm Glass or 2 mm Plastic Panels
  • Activation Flow Rate:

    1.2 L/min
  • Shutoff Flow Rate:

    1.0 L/min

# HS-DHH-EPC13-TV-XH5-P1.0 Three-Key Instant Electric Water Heater PCBA

The HS-DHH-EPC13-TV-XH5-P1.0 is a three-key instant electric water heater PCBA designed for point-of-use water-heating appliances with a maximum power setting of 7 kW. Combined with the HS-DHH-3526C-3KEY-XH5-C1.0 display board, this control solution integrates wide-voltage operation, digital temperature regulation, water-flow sensing, automatic constant-temperature learning, parameter memory, and multiple fault-protection functions.

Its compact three-key interface and configurable control program make it suitable for electric shower heaters, wall-mounted instant water heaters, kitchen and washbasin heaters, and customized OEM or ODM water-heating equipment.

## Wide-Voltage Power Supply

The standard switching-power-supply solution supports an input voltage range of 85–280 VAC. During internal sample verification, the controller operated continuously at 280 VAC for eight hours without abnormal behavior.

An optional transformer solution supports 180–265 VAC and completed eight hours of continuous operation at 265 VAC. Manufacturers can select the appropriate power supply according to the target market, product structure, cost requirements, and applicable electrical standards.

## Configurable Power and Level Settings

The controller provides four selectable power configurations: P4, P5, P6, and P7. The P7 setting corresponds to a maximum power output of 7,000 W. The exact power mappings for P4, P5, and P6 can be confirmed during the product-development stage according to the selected heating element and complete-appliance design.

The power-setting menu is accessed by pressing and holding the increase and decrease keys together for five seconds. A separate L0–L6 mode provides seven selectable control levels and can be entered or exited by holding the power key for three seconds.

Final rated output must be confirmed based on the complete appliance, including the heating element, switching device, wiring, terminals, cooling conditions, and thermal-protection design.

## Simple Three-Key Control Interface

The display board provides three primary keys:

- KEY1: Temperature Increase

- KEY2: Power On/Off

- KEY3: Temperature Decrease

Pressing and holding the increase or decrease key for more than one second enables continuous adjustment. Each valid key operation is confirmed by an audible buzzer signal.

The touch-control interface is compatible with installation behind either a 4 mm glass panel or a 2 mm plastic panel, giving appliance manufacturers greater flexibility in front-panel and enclosure design.

## Digital Display and Operating Status

After power is connected, the digital display performs a one-second full-segment check accompanied by a buzzer tone. The display then enters standby mode until the appliance is switched on.

During operation, the screen can display the actual outlet-water temperature and the selected temperature. Each press of the increase or decrease key changes the temperature by one degree. After three seconds without further operation, the display automatically returns to the actual outlet-water temperature.

A decimal-point indicator shows active water flow and heating status. When excessive water flow is detected, the display shows “LL,” helping users identify conditions that may reduce heating performance.

## Water-Flow Detection

The controller automatically activates heating when the detected water flow reaches approximately 1.2 L/min. Heating is switched off when the flow falls to approximately 1.0 L/min.

These thresholds help prevent heating when the available water flow is insufficient while allowing the appliance to respond quickly when a hot-water outlet is opened.

## Automatic Constant-Temperature Control

The PCBA provides an adjustable temperature range of 30–55°C. A 50K NTC inlet-water temperature sensor is used for temperature monitoring and can operate normally at temperatures down to -15°C.

The control program supports automatic constant-temperature learning, calibration, and parameter memory. The selected temperature and power settings can be retained after the appliance is switched off, improving convenience during repeated use.

During internal sample testing with 26°C inlet water, the controller was evaluated at set temperatures of 30°C, 36°C, 40°C, 45°C, and 48°C under flow rates of 1.5 L/min and 3.0 L/min. The measured outlet temperatures were approximately -1°C to +2°C from the selected values. After initial learning and calibration, temperature stabilization was achieved within 20 seconds under the specified test conditions.

## Protection and Fault Diagnostics

The controller integrates multiple monitoring and protection functions:

- Overtemperature protection: Heating stops with an alarm when the temperature reaches 63°C or above and resumes automatically when it falls to 50°C.

- Leakage protection: Heating is disabled and an alarm is generated when leakage is detected.

- Outlet-temperature sensor protection: Heating stops if an open- or short-circuit condition is detected and resumes automatically after recovery.

- Inlet-temperature sensor monitoring: An alarm is generated if an open- or short-circuit condition is detected, with constant-temperature relearning available after the fault is cleared.

- Zero-crossing detection: Heating is disabled when a zero-crossing fault is detected.

- Communication-fault protection: Heating stops and an alarm is generated if communication becomes abnormal.

- Excessive-flow indication: “LL” is displayed when the detected water flow is too high.

Fault codes including E0, E1, E3, E4, and E9 provide clear diagnostic information for production testing, servicing, and after-sales support.

## Internal Sample Verification

The engineering sample completed a series of functional and reliability checks, including:

- Eight-hour continuous operation at 280 VAC

- Eight-hour transformer-solution operation at 265 VAC

- Eight-hour operation at 65°C and 90% relative humidity

- Complete-appliance dielectric testing at 1,800 V and 5 mA for one minute

- Thirty fluorescent-lamp switching interference cycles at intervals of 0.5–3 seconds

- Normal-temperature and recirculating-water testing

The reported operating environment is -15°C to 65°C with 10–95% relative humidity. No abnormal behavior was recorded during the stated sample tests. These results represent internal engineering verification and do not constitute third-party product certification.

## Application Scenarios

This three-key instant electric water heater PCBA can be used in:

- Electric shower heaters

- Wall-mounted instant water heaters

- Kitchen and washbasin water heaters

- Residential point-of-use heating appliances

- Commercial handwashing and sanitation equipment

- Customized OEM and ODM water-heating products

## OEM and ODM PCBA Manufacturing

With 15 years of PCBA development and manufacturing experience, SunSam provides integrated services covering hardware design, firmware development, prototype production, SMT assembly, wave soldering, display-board manufacturing, functional testing, traceability, and volume production.

The key layout, display content, power configuration, temperature range, flow thresholds, fault logic, buzzer settings, and control program can be customized according to the customer’s appliance requirements.

The HS-DHH-EPC13-TV-XH5-P1.0 offers a practical platform for manufacturers seeking a customizable 7kW water heater control board with wide-voltage operation, intelligent temperature control, water-flow sensing, and comprehensive fault management.

Send Inquiry
Contact Info
  • Address

    Phase I of TianfuLai International Industrial City, Rongui Town, Shunde District, Foshan City, Guangdong Province, China

  • Tel

Foshan Shunde SunSam Electronic Co., Ltd.
Phase I of TianfuLai International Industrial City, Rongui Town, Shunde District, Foshan City, Guangdong Province, China

Looking for a reliable PCBA supplier? Contact SUNSAM for customized PCBA heater, PCBA refrigeration and washing machine PCBA, free samples, and competitive wholesale pricing. Get a quick quotation today.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept