HS-NXS-04SXH Instant Electric Water Heater PCBA

Designed for pump-assisted instant electric water heaters, this customizable three-key PCBA supports 65–280 VAC input, 30–55°C control, pump pre-run and delayed shutdown, four-wire flow sensing, temperature memory, optional negative-ion synchronization, and fault protection.
  • Power Supply:

    Switching Power Supply Solution
  • Input Voltage:

    65–280 VAC
  • Optional Power Supply:

    Transformer Solution
  • Optional Input Voltage:

    85–280 VAC
  • Temperature Setting Range:

    30–55°C
  • Activation Flow Rate:

    1.4 L/min
  • Shutoff Flow Rate:

    1.2 L/min
  • Touch Panel Compatibility:

    4 mm Glass or 2 mm Plastic Panel
  • Operating Temperature Range:

    −15°C to 65°C
  • Operating Humidity Range:

    10–95% RH

# HS-NXS-04SXH-P1.0B Pump-Controlled Instant Electric Water Heater PCBA

The HS-NXS-04SXH-P1.0B is a customizable instant electric water heater PCBA designed for water-heating systems that require coordinated pump, heating, flow-sensing, and optional negative-ion control.

Combined with the HS-HX-HW8848XK-C2.3 display board, the solution provides three-key touch operation, intelligent temperature regulation, pump pre-circulation, delayed pump shutdown, real-time operating information, parameter memory, and fault protection. Both boards use APT control ICs.

## Wide-Voltage Power Supply

The standard switching power supply version supports an input voltage range of 65–280 VAC. An optional transformer-based solution supporting 85–280 VAC is also available for different appliance designs and regional power conditions.

During internal sample verification, the switching power supply version operated continuously for eight hours at 280 VAC without abnormal behavior. The transformer solution also completed an eight-hour continuous operation test at 265 VAC.

## Simple Three-Key Control

The controller uses a straightforward three-key interface:

- Temperature decrease

- Power on/off

- Temperature increase

Pressing and holding the increase or decrease key for more than one second enables continuous temperature adjustment. Each valid key operation is confirmed by an audible buzzer tone.

The touch interface can operate through a 4 mm glass panel or a 2 mm plastic panel, allowing it to be integrated into different appliance housings and front-panel designs.

## Pump Pre-Run and Delayed Shutdown

The pump-control sequence is designed to establish water circulation before heating and continue circulation briefly after heating stops.

After the unit is switched on, the pump runs for ten seconds before the heating element is activated. When the unit is switched off, heating stops first, and the pump continues running for another three seconds before shutting down.

If no water flow is detected, the pump stops automatically after ten seconds. This operating sequence helps coordinate the water circuit and heating system while reducing unintended heating without sufficient circulation.

## Intelligent Temperature Control

The adjustable temperature range is 30–55°C, with an initial default setting of 38°C. A 50K NTC sensor is used for temperature detection, while the control program supports automatic temperature learning, calibration, and parameter memory.

The tested activation flow rate is 1.4 L/min, and the controller uses a four-wire flow switch for water-flow detection.

Under sample test conditions with a 26°C inlet temperature and flow rates of 1.5–3.0 L/min, the tested 30–48°C setpoints stabilized within 20 seconds after initial learning and calibration.

## Detailed Operating Display

After power is applied, the buzzer sounds once and the display performs a one-second full-screen check. During operation, the display can indicate:

- Intelligent constant-temperature status

- Actual outlet water temperature

- Selected temperature

- Inlet water temperature

- Water-flow status

- Energy usage information

- Pump and heating status

Animated arc and shower icons indicate that the pump and heating system are operating. Static icons indicate that no water flow is detected and the appliance is inactive.

## Optional Negative-Ion Synchronization

The controller also supports synchronized negative-ion operation. When the appliance is operating, the negative-ion function can be activated automatically. When the appliance stops, the negative-ion function is switched off.

This feature is intended for complete appliances equipped with a compatible negative-ion generator and the required control interface.

## Fault Detection and Protection

The PCBA supports several diagnostic and protection functions, including:

- Pump wiring or connection fault detection

- Outlet temperature sensor open-circuit detection

- Outlet temperature sensor short-circuit detection

- Zero-crossing fault handling

- Communication fault detection

- Leakage-current detection

- Audible fault warning

- Heating shutdown during critical faults

The leakage detection range specified in the sample report is 15–30 mA. The final trigger threshold and tolerance should be defined according to the production leakage coil and firmware configuration.

## Sample Reliability Verification

The sample completed several internal verification tests, including:

- Eight-hour continuous operation at 280 VAC

- Eight-hour testing at 65°C and 90% RH

- Complete-appliance dielectric testing at 1,800 V and 5 mA for one minute

- Fluorescent-lamp switching interference testing repeated 30 times

- Normal-temperature water testing

- Circulating-water testing

- Constant-temperature testing at different temperatures and flow rates

The specified controller operating environment is −15°C to 65°C with a relative humidity range of 10–95% RH.

## Application Scenarios

This pump-controlled instant electric water heater PCBA is suitable for:

- Pump-assisted instant electric water heaters

- Instant electric shower systems

- Water heaters requiring controlled pre-circulation

- Wall-mounted household water heaters

- Commercial point-of-use water heaters

- Water-heating equipment with negative-ion functions

- Customized OEM and ODM hot-water appliances

## OEM and ODM PCBA Manufacturing

With 15 years of PCBA manufacturing and product development experience, SunSam provides hardware development, firmware programming, SMT assembly, wave soldering, display-board production, functional testing, traceability management, and volume manufacturing services.

Pump timing, temperature ranges, display icons, key functions, sensor logic, protection thresholds, connectors, board dimensions, negative-ion control, and firmware behavior can be customized according to the customer’s complete appliance design.

From prototype verification to volume production, SunSam provides complete instant electric water heater PCBA solutions for appliance manufacturers and brand customers.

Send Inquiry
Contact Info
  • Address

    Phase I of TianfuLai International Industrial City, Rongui Town, Shunde District, Foshan City, Guangdong Province, China

  • Tel

Foshan Shunde SunSam Electronic Co., Ltd.
Phase I of TianfuLai International Industrial City, Rongui Town, Shunde District, Foshan City, Guangdong Province, China

Looking for a reliable PCBA supplier? Contact SUNSAM for customized PCBA heater, PCBA refrigeration and washing machine PCBA, free samples, and competitive wholesale pricing. Get a quick quotation today.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept