Products
HS-QL-SM 8.5kW Instant Electric Water Heater PCBA
  • HS-QL-SM 8.5kW Instant Electric Water Heater PCBAHS-QL-SM 8.5kW Instant Electric Water Heater PCBA

HS-QL-SM 8.5kW Instant Electric Water Heater PCBA

This three-key instant electric water heater PCBA supports 65–280 VAC input, configurable P6–P8 power settings up to 8.5 kW, 30–55°C temperature control, 42°C default operation, flow sensing, parameter memory, leakage monitoring, and multi-fault protection for customized heaters.
  • Standard Power Supply:

    Switching Power Supply: 65–280 VAC
  • Optional Power Supply:

    Transformer Solution: 180–265 VAC
  • Maximum Power Setting:

    8,500 W
  • Temperature Setting Range:

    30–55°C
  • Activation Flow Rate:

    1.8 L/min
  • Shutoff Flow Rate:

    1.5 L/min
  • Operating Temperature Range:

    -15°C-65°C
  • Operating Humidity Range:

    10%–95% RH

# HS-QL-SM-P1.9 Three-Key 8.5kW Instant Electric Water Heater PCBA

The HS-QL-SM-P1.9 is a three-key instant electric water heater PCBA developed for high-power, point-of-use water-heating appliances. Combined with the HS-NXS-5680-XH3-C1.0 display board, it provides power configurations up to 8.5 kW, wide-voltage operation, digital temperature adjustment, intelligent water-flow detection, automatic constant-temperature learning, parameter memory, and integrated fault protection.

The power board uses an APT control IC, while the display board adopts a 28-pin BYD display IC. Its configurable hardware and firmware make the solution suitable for electric shower heaters, wall-mounted instant water heaters, kitchen heaters, washbasin heaters, and customized OEM or ODM water-heating equipment.

## Wide-Voltage Power Supply

The standard switching-power-supply solution supports an input voltage range of 65–280 VAC. During internal sample verification, the controller operated continuously at 280 VAC for eight hours without abnormal behavior.

An optional transformer solution supports 180–280 VAC and completed eight hours of continuous operation at 265 VAC. Manufacturers can select the appropriate power supply according to the target market, appliance structure, cost requirements, and applicable electrical standards.

## Configurable Power Settings up to 8.5 kW

The controller provides three selectable power configurations: P6, P7, and P8. The P8 setting corresponds to a maximum power of 8,500 W.

With the appliance switched off, pressing and holding the temperature-increase and temperature-decrease keys together for five seconds opens the power-setting menu. This design helps prevent users from entering the configuration menu accidentally during normal operation.

The sample report specifies 8,500 W for P8. The exact wattage mappings for P6 and P7 should be confirmed during the product-development stage based on the heating element, switching components, wiring, terminals, cooling conditions, and complete-appliance design.

## Simple Three-Key Control Interface

The display board provides three primary control keys:

- K1: Temperature Decrease

- K2: Power On/Off

- K3: Temperature Increase

Pressing and holding the temperature-increase or temperature-decrease key for more than one second enables continuous adjustment. Each valid key operation is confirmed by an audible buzzer signal.

The touch-control interface can be installed behind either a 4 mm glass panel or a 2 mm plastic panel, allowing manufacturers to integrate the controller into different front-panel and enclosure designs.

## Digital Temperature and Water-Flow Display

After power is connected, the digital screen performs a one-second full-display check accompanied by a buzzer tone. The controller then enters the power-off state and retains the previously selected temperature and power settings.

The display can show the set temperature, inlet-water temperature, outlet-water temperature, operating status, and fault information. The default temperature is 42°C, while the adjustable temperature range is 30–55°C.

When water flow is detected, the shower and circular display icons provide animated operating feedback. Without water flow, the shower icon turns off and the circular indicator remains static.

## Automatic Water-Flow Detection

The controller uses an activation flow rate of approximately 1.8 L/min and a shutoff flow rate of approximately 1.5 L/min. A 3+2-wire flow switch is used for flow detection and system control.

Heating starts automatically when sufficient water flow is detected and stops when the flow falls below the shutoff threshold. This logic helps prevent heating under insufficient-flow conditions and supports stable operation during normal use.

## Constant-Temperature Regulation

A 50K NTC inlet-water temperature sensor provides temperature feedback for the control program. The sensor operates normally at temperatures down to -15°C.

The firmware supports automatic constant-temperature learning, calibration, and parameter memory. In selected applications, constant-temperature control can continue if the inlet sensor is removed or becomes abnormal, except for heat-recovery systems that require inlet-temperature feedback.

During internal testing with 26°C inlet water, the controller was evaluated at settings of 30°C, 36°C, 40°C, 45°C, and 48°C under flow rates of 1.5 L/min and 3.0 L/min.

The measured outlet temperatures were approximately -1°C to +2°C from the selected values. Depending on the temperature and flow rate, the recorded stabilization time was approximately 5–20 seconds after initial learning and calibration.

## Protection and Fault Diagnostics

The HS-QL-SM-P1.9 integrates multiple monitoring and protection functions:

- Overtemperature protection: Heating stops with an alarm at 63°C or above and resumes automatically when the temperature falls to 50°C.

- Leakage protection: Heating is disabled and an alarm is generated when leakage is detected.

- Outlet-temperature sensor protection: Heating stops if an open- or short-circuit condition is detected and resumes automatically after recovery.

- Inlet-temperature sensor monitoring: An alarm is generated if an open- or short-circuit condition is detected, while heating can continue according to the programmed control logic.

- Zero-crossing fault management: The controller switches to a cycle-skipping heating strategy when the zero-crossing signal becomes abnormal.

- Communication-fault protection: Heating stops when a communication fault is detected.

Fault codes E0, E1, E2, E3, E4, and 00 provide diagnostic information for production testing, servicing, and after-sales troubleshooting.

The leakage-detection circuit has a specified monitoring range of 15–30 mA, with a measured sample value of 24 mA. The final threshold must be matched to the complete appliance and the safety requirements of the intended market.

## Internal Sample Verification

The engineering sample completed several functional and reliability checks, including:

- Eight-hour continuous operation at 280 VAC

- Eight-hour transformer-solution operation at 265 VAC

- Eight-hour operation at 65°C and 90% relative humidity

- Complete-appliance dielectric testing at 1,800 V and 5 mA for one minute

- Thirty fluorescent-lamp switching interference cycles at intervals of 0.5–3 seconds

- Relay control testing

- Normal-temperature and recirculating-water testing

The reported operating environment is -15°C to 65°C with 10%–95% relative humidity. No abnormal behavior was recorded during the stated sample tests.

These results represent internal engineering sample verification and do not constitute third-party product certification.

## Application Scenarios

This three-key instant electric water heater PCBA can be customized for:

- Electric shower heaters

- Wall-mounted instant water heaters

- Kitchen and washbasin water heaters

- Residential point-of-use heating appliances

- Commercial handwashing and sanitation equipment

- OEM and ODM water-heating products

## OEM and ODM PCBA Manufacturing

With 15 years of PCBA development and manufacturing experience, SunSam supports customers from product definition and circuit development to prototype verification and volume production.

Available services include hardware design, firmware development, SMT assembly, wave soldering, display-board production, functional testing, ICT and FCT coordination, component quality management, and production traceability.

The power configuration, temperature range, key layout, display content, flow thresholds, fault logic, sensor configuration, and control program can be customized according to the customer’s appliance structure and market requirements.

The HS-QL-SM-P1.9 provides a flexible platform for manufacturers seeking an 8.5kW water heater control board with wide-voltage operation, stable temperature regulation, water-flow sensing, parameter memory, and integrated protection.

Send Inquiry
Contact Info
  • Address

    Phase I of TianfuLai International Industrial City, Rongui Town, Shunde District, Foshan City, Guangdong Province, China

  • Tel

Foshan Shunde SunSam Electronic Co., Ltd.
Phase I of TianfuLai International Industrial City, Rongui Town, Shunde District, Foshan City, Guangdong Province, China

Looking for a reliable PCBA supplier? Contact SUNSAM for customized PCBA heater, PCBA refrigeration and washing machine PCBA, free samples, and competitive wholesale pricing. Get a quick quotation today.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept